Fault messages, causes and remedies
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
83
8 Fault messages, causes and remedies
Pos: 65 /Schw eissnaht/Geräte/ SND40/9 Fe hlermeldungen/ Fehlermel dungen @ 0\mod _114361831 7062_501.do cx @ 1993 @ 22 @ 1
Text of error message
Error No.
via Field bus
Possible cause Remedy
Error while initialization of WIN sockets. - Windows system error Re-install Windows CE
Unknown error. - Unspecific error. Re-start
Invalid data received. 20
Processor module is sending
invalid data. Bus connection or
hardware might be defective.
Check RS232 connection between
processor module and communication
module – change hardware.
System configuration was not
converted.
-
Invalid values for system
settings or memory error.
Check / re-enter parameters, change
hardware if required.
File error. -
File cannot be read or has a
wrong format.
Create the program newly.
Internal error. - Unspecific error. Re-start.
Program initialization failed. - Error in the program file. Re-teach.
Frequency table not loaded. - Error in the frequency file. Re-install.
System configuration was not stored. - Error in Flash. Change KM hardware.
System configuration was not loaded. - Error in the system file.
Re-enter system parameters or change
KM hardware.
Unable to copy program. -
File already existing, insufficient
memory space
or error in Flash.
Delete unused files,
check name.
Unable to store program. -
File already existing, insufficient
memory space
or error in Flash.
Delete unused files,
check name.
No active program. - No valid program selected. Select a valid program.
Invalid program number. - No valid program selected.
Program parameter xxx invalid.
xxx = no. of parameter
(see rank in program file).
20 Special parameter is invalid. Re-enter parameter.
System parameter xxx invalid.
xxx = no. of parameter
(see rank in system file).
- Special parameter is invalid. Re-enter parameter.
Parameter xxx in system settings
invalid. Please modify and restart
system.
xxx = designation of parameter, e.g.
“Language”.
- Special parameter is invalid. Re-enter parameter.
Unable to save job. -
File already existing, insufficient
memory space
or error in Flash.
Delete unused files, check name.
Invalid groups. 20
Data quantity of groups (auto
correlation) does not match.
Delete program, re-teach.
PM: receive buffer overflow. 95 Too much data to proc. module.
Check RS232 connection / Hardware
error.
PM: character not in hex format. Error at data transmission.
PM: message error - no STX. Error at data transmission.
PM: message – checksum wrong Error at data transmission.