Fault messages, causes and remedies
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
83
8 Fault messages, causes and remedies
Pos: 65 /Schw eissnaht/Geräte/ SND40/9 Fe hlermeldungen/ Fehlermel dungen @ 0\mod _114361831 7062_501.do cx @ 1993 @ 22 @ 1
Text of error message
Error No.
via Field bus
Possible cause Remedy
Error while initialization of WIN sockets. - Windows system error Re-install Windows CE
Unknown error. - Unspecific error. Re-start
Invalid data received. 20
Processor module is sending
invalid data. Bus connection or
hardware might be defective.
Check RS232 connection between
processor module and communication
module change hardware.
System configuration was not
converted.
-
Invalid values for system
settings or memory error.
Check / re-enter parameters, change
hardware if required.
File error. -
File cannot be read or has a
wrong format.
Create the program newly.
Internal error. - Unspecific error. Re-start.
Program initialization failed. - Error in the program file. Re-teach.
Frequency table not loaded. - Error in the frequency file. Re-install.
System configuration was not stored. - Error in Flash. Change KM hardware.
System configuration was not loaded. - Error in the system file.
Re-enter system parameters or change
KM hardware.
Unable to copy program. -
File already existing, insufficient
memory space
or error in Flash.
Delete unused files,
check name.
Unable to store program. -
File already existing, insufficient
memory space
or error in Flash.
Delete unused files,
check name.
No active program. - No valid program selected. Select a valid program.
Invalid program number. - No valid program selected.
Program parameter xxx invalid.
xxx = no. of parameter
(see rank in program file).
20 Special parameter is invalid. Re-enter parameter.
System parameter xxx invalid.
xxx = no. of parameter
(see rank in system file).
- Special parameter is invalid. Re-enter parameter.
Parameter xxx in system settings
invalid. Please modify and restart
system.
xxx = designation of parameter, e.g.
“Language”.
- Special parameter is invalid. Re-enter parameter.
Unable to save job. -
File already existing, insufficient
memory space
or error in Flash.
Delete unused files, check name.
Invalid groups. 20
Data quantity of groups (auto
correlation) does not match.
Delete program, re-teach.
PM: receive buffer overflow. 95 Too much data to proc. module.
Check RS232 connection / Hardware
error.
PM: character not in hex format. Error at data transmission.
PM: message error - no STX. Error at data transmission.
PM: message checksum wrong Error at data transmission.