Jan. 2005 RD-700SX
CHECKING THE VERSION
NUMBER
1. Turn on the power to the RD-700SX.
2. After the unit starts up, press [CURSOR ] + [ZONE SELECT LOWER] +
[EDIT].
This puts the RD-700SX in Test mode.
Upon entering Test mode, the following screen appears.
fig.09-test01.eps
Turn the power off and then on again to return to normal operating
mode.
USERS DATA SAVE AND LOAD
Transferring the RD-700SX’s
Settings to an External MIDI
Device (Bulk Dump)
You can transfer the contents of Setups and the RD-700SX’s system settings to
an external MIDI device. This operation is called “bulk dump.”
Use this procedure to save the data to an external MIDI device in situations
such as when you want to perform by connecting another RD-700SX with the
same settings, or to prevent your Setups and system settings from corruption.
1. Use a MIDI cable (optional) to connect the RD-700SX’s MIDI OUT
connector to the MIDI IN connector on an external sequencer.
2. Press [EDIT], getting its indicator to light.
The Edit Menu screen appears.
fig.10-01EditMenu2.eps
3. Press CURSOR [ ] and select the [9.Utility].
4. Press [ENTER] to display the Edit screen.
fig.10-02e-Utility1.eps
5. Press CURSOR [ ]/[ ] to select the [1. Bulk Dump Temporary]
or [2. Bulk Dump SETUP]
Bulk Dump Temporary
6. Press [ENTER].
A screen like the one shown below appears.
fig.10-03e-BulkTemp1.eps
7. Put the external sequencer in record mode.
8. Press [ENTER] to transmit the settings.
To cancel the Bulk Dump, press [DEC].
The message “Now, Executing...” appears in the display during
transmission of the data.
9. After the transmitting is finished, the display will indicate “COMPLETE!.”
You are returned to the Edit screen.
10. Stop the external sequencer.
Bulk Dump SETUP
6. Press [ENTER].
A screen like the one shown below appears.
fig.10-04e-BulkSetup2.eps
7. Press CURSOR [ ] / [ ] and [INC]/[DEC] to set the
transmitted Setups
8. Put the external sequencer in record mode.
9. Press [ENTER] to transmit the settings.
To cancel the Bulk Dump, press [DEC].
A screen like the one shown below appears.
fig.10-05e-BulkSetup3.eps
10. After the transmitting is finished, the display will indicate “COMPLETE!.”
You are returned to the Edit screen.
11. Stop the external sequencer.
Restoring saved settings to the RD-700SX
When returning settings saved to an external sequencer back to the RD-700SX,
an Exclusive message is transmitted from the external sequencer, then the data
is received by the RD-700SX.
Be aware that when you restore Setups data to the RD-700SX, the data in the
RD-700SX will be overwritten and lost.
1. Use a MIDI cable to connect the MIDI OUT connector of the external
sequencer to the MIDI IN connector of the RD-700SX.
2. Set the device ID number to the same setting as when you performed the
bulk dump.
Setting the Device ID Number “Setting the Device ID Number (Device ID)” .
DISPLAY MEANING
Product Name: CD00C
PRG Version No: Program version number
PRG Build No: Program build number
Booter Version: Booter Version number
Parameter Value
Bulk Dump Temporary The contents of the currently selected Set-
up are transmitted.
Bulk Dump SETUP The contents of Setups in the specified
range are transmitted.
Parameter Value
From Setup number for the first Setup to be transmitted.
To Setup number for the last Setup to be transmitted.
Send System Determines whether the system settings are to be
transmitted (YES), or not (NO).