22
Jan. 2005 RD-700SX
SYSTEM SOFTWARE
UPDATING INSTRUCTIONS
Required Equipment
• RD-700SX UPDATE DISK (#17041561)
• USB cable
• PC equipped with CD-ROM drive (OS: Windows XP/2000 or later) with
“RD USB DRIVER” and simple SMF player “UpdSMFJ.exe” installed
Procedure
• Hold down the [EDIT] and [NUMLOCK] buttons and turn on the power
to the RD-700SX.
The following screen appears in the LCD screen.
To cancel the update at this point, turn off the power to the RD.
• Power up the PC.
• After the PC has started up, connect the RD and the PC with a USB cable.
• Place the RD-700SX UPDATE DISK in the PC.
• Start up the “UpdSMFJ.exe” simple SMF player.
• Make the following settings for UpdSMF.
[MIDI OUT Device]
→ Select Roland RD.
[SMF Path]
→ Specify your computer’s CD-ROM drive.
Click [Scan SMF].
→ Confirm that “rd700sx_v***.mid” is indicated in the listed column.
“***” refers to the updater version.
Example: rd700sx_v103.mid in the updater Ver. 1.03.
• After completing the above settings, click the UpdSMF [Send] button.
The RD’s LCD starts to flash when transfer of the data begins.
Do not turn off the power to the RD or disconnect the USB cable once data
transfer has begun.
• Once the data transfer is completed, the RD loads the data to the
Program ROM.
During loading to the Program ROM, the following screen appears in the
LCD display, and all of the panel LEDs remain lit.
Do not turn off the power to the RD while data is being loaded.
This may corrupt the ROM image, and in the worst case may make restoration
of the main board impossible.
• Once loading to the ROM is completed, the following screen appears in
the LCD display, and all of the panel LEDs flash.
After confirming that the above screen is displayed and the LEDs are
flashing, disconnect the USB cable, then turn off the power to the RD.
This completes the update.
TEST MODE
Required Equipment
• SRX expansion boards (2)
• Monitor speakers
• Headphones
• Audio cable (w/standard phone plugs)
• Audio cable (w/Cannon (XLR) connectors)
• MIDI cable
• USB cable
• DP-8
•PC
Precautions to Note Before Testing
• Be sure to back up the user data before testing.
• Install the SRX expansion boards before turning on the power to the RD-
700SX.
Installing the boards with the power on may corrupt the boards.
• Install the “RD USB Driver” and a software synthesizer (e.g., VMT) on
the PC to be use for the USB connection check before beginning the test
procedure.
Entering Test Mode
1. Turn on the power to the RD-700SX.
2. After the power is on, press [CURSOR →], [ZONE SELECT LOWER], and
[EDIT].
Selecting Test Mode Categories
Specific tests can be selected from the categories listed below by pressing the
[EDIT] button and the [TONE SELECT] button 0--9 corresponding to the
desired test.
Tests can also be selected sequentially with [EDIT] and [CURSOR ←]/
[CURSOR →].
SG Check :[EDIT]+[0]
SW/LED Check1 :[EDIT]+[1]
SW/LED Check2 :[EDIT]+[2]
Bender/Pedal Check :[EDIT]+[4]
Volume Check :[EDIT]+[5]
LCD Check :[EDIT]+[3]
MIDI Check :[EDIT]+[6]
Sound Check :[EDIT]+[7]
Device Check :[EDIT]+[8]
Factory Reset :[EDIT]+[9]
Vendor Driver
Writing
Writing Done