EasyManua.ls Logo

Roland SH-201 - Basic Structure of the SH-201; Controller Section; Sound Generator Section

Roland SH-201
43 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
May 2006 SH-201/SH-201C
Required Items
PC in which “UpdSMF” is installed (Refer to the Service Information
#102333 for UpdSMF.)
USB driver for SH-201
USB cable
Procedure of Update
Before executing the procedure of updating, follow the
Users Data Save and
Load
(p. 14) to save patch data.
Never turn off the power of SH-201 while executing update. SH-201 system
may not boot up correctly.
1.
Make sure the power of SH-201 is off, and then connect PC to the SH-201
with a USB cable.
2.
While holding down the [OVERDRIVE] and [FX ON] buttons at the
upper right on the SH-201 top panel, turn on the power.
3.
Confirm the LED of the [TAP] button lights.
4.
Double-click the icon of “UpdSMF.exe.”
5.
Select Roland SH-201 in “MIDI Out Device.”
6.
Set the name of the uncompressed SMF folder at “SMF Path.” You can
also search the folder by the [Path] button at the right side.
7.
Click the [ScanSMF] button.
8.
Click the [Send] button.
Registered SMFs are played back and sent in order. When the SH-201
receives the SMF, the [OCT DOWN] button will blink.
After eight or nine minutes, transmitting of SMF is finished and then
update procedure will begin.
After a while, all of the LEDs of BANK [A]–[D] and NUMBER [1]–[8] will
blink in green.
9.
After confirming the blinking in green, turn off the power.
* If the LED of BANK [A]–[D] and NUMBER [1]–[8] blink in red, updating is a
failure. Execute the update procedure from the first step again.
10.
Refer to
Checking the Version Number
(p. 14), and check the version
has been updated.
11.
Refer to
Users Data Save and Load
(p. 14), load the User Patch which
has been saved in PC.
Initialize
You can’t initialize the entire system of SH-201 without executing Factory
Reset.
Test Mode
After executing the Test Mode, patch data in SH-201 will be lost and SH-201
will return to the condition when shipping. If there are important data in the
SH-201, save them to PC using the backup function for User Data. (Refer to
Users Data Save and Load
(p. 14).)
Required Items
Headphones
Noise Meter
PC (with a USB connector, OS: Windows Me/2000/XP, installed the USB
driver for SH-201)
USB Cable x 1
MIDI Cable x 1
Audio Cable x 2
Monitor Speaker
Expression Pedal (EV-5)
oscilloscope
Oscillator

Other manuals for Roland SH-201

Related product manuals