Individual parameter
You can use individual parameter communication to send or request an individual parameter value.
One packet of System Exclusive messages "F0 ..... F7" can only have one parameter (which may contain several bytes).
You cannot use any address having "#" for the top address in a System Exclusive message.
•System Parameters
Address(H) Size(H) Data(H) Parameter Description Default Value (H) Description
=======================================================================================================
40 00 00 00 00 04 0018 - 07E8 MASTER TUNE -100.0 - +100.0 [cent] 00 04 00 00 0 [cent]
40 00 01# Use nibblized data.
40 00 02#
40 00 03#
40 00 04 00 00 01 00 - 7F MASTER VOLUME 0 - 127 7F 127
40 00 05 00 00 01 28 - 58 MASTER KEY-SHIFT -24 - +24 [semitones] 40 0 [semitones]
40 00 06 00 00 01 01 - 7F MASTER PAN 40 Center
40 00 7F 00 00 01 00, 7F MODE SET 00 = GS Reset
(Rx Only) 127 = Exit GS
Refer to "System Exclusive Messages of Mode Change" (Page 46)
•Patch Parameters
SK-50 has 16 parts. The parameters of each part are called PATCH PARAMETERS.
To send or request a PATCH PARAMETER, use not the part number (which is usually same as the MIDI channel number) but the BLOCK NUMBER in
the message.
*x...BLOCK NUMBER (0 - F), Part 1 (default MIDIch = 1) x=1
Part 2 (default MIDIch = 2) x=2
: : :
Part 9 (default MIDIch = 9) x=9
Part10 (default MIDIch =10) x=0
Part11 (default MIDIch =11) x=A
Part12 (default MIDIch =12) x=B
: : :
Part16 (default MIDIch =16) x=F
*n...MIDI channel number (0 - F) of the BLOCK.
Address(H) Size(H) Data(H) Parameter Description Default Value (H) Description
=======================================================================================================
40 01 10 00 00 10 00 - 18 VOICE RESERVE Part 10(Drum Part) 02 2
40 01 11# Part 1 06 6
40 01 12# Part 2 02 2
40 01 13# Part 3 02 2
40 01 14# Part 4 02 2
40 01 15# Part 5 02 2
40 01 16# Part 6 02 2
40 01 17# Part 7 02 2
40 01 18# Part 8 02 2
40 01 19# Part 9 02 2
40 01 1A# Part 11 02 2
40 01 1B# Part 12 02 2
40 01 1C# Part 13 00 0
40 01 :# :
40 01 1F# Part 16 00 0
The sum total of voices in the voice reserve function must be equal or less than the number of the maximum polyphony. The number of the
maximum polyphony of SK-50 is 28.
For the compatibility to other GS models, it is recommended to be equal or less than 24.
40 01 30 00 00 01 00 - 07 REVERB MACRO 00: Room 1 04 Hall 2
01: Room 2
02: Room 3
03: Hall 1
04: Hall 2
05: Plate
06: Delay
07: Panning Delay
40 01 31 00 00 01 00 - 07 REVERB CHARACTER 0-7 04 4
40 01 32 00 00 01 00 - 07 REVERB PRE-LPF 0-7 00 0
40 01 33 00 00 01 00 - 7F REVERB LEVEL 0-127 40 64
40 01 34 00 00 01 00 - 7F REVERB TIME 0-127 40 64
40 01 35 00 00 01 00 - 7F REVERB DELAY FEEDBACK 0-127 00 0
40 01 36 00 00 01 00 - 7F REVERB SEND LEVEL TO CHORUS 0-127 00 0