Page 26
System configuration
© 2017 Ropam Elektronik
Input settings - Analog I7, I8.
In addition, two inputs I7, I8 are binary / analog inputs that can be configured from BasicGSM
Manager.
These inputs can, in addition to the binary states (0,1), recognize the values of analog signals: 0-10 [V]
and 4-20 [mA].
When selecting I7 or I8 input mode as analog:
you must configure its parameters:
- name - easier identification of the measured value
- Alarm when higher / lower than allowed (SMS, CLIP, e-mail notification) of required content.
It is also possible to set the voice prompts of the VSR-2 module connected to the module or to use
audio messages recorded to the files and uploaded to the module memory (Tab "Communications,
Tests, Counters" option: Audio voice announcements).
- Input hysteresis: set to delay the input to change input parameters.
- Delay [ms]: delay in response to change of measured value.