Quick Start Guide
00825-0200-4802, Rev HC
August 2016
Rosemount
3051S Series Pressure Transmitter
and Rosemount 3051SF Series Flowmeter
with WirelessHART
®
Protocol

Questions and Answers:

Rosemount 3051S Series Specifications

General IconGeneral
TypePressure Transmitter
Temperature Range-40 to 185 °F (-40 to 85 °C)
AccuracyUp to ±0.025% of span
Output4-20 mA HART, FOUNDATION Fieldbus
Process Connection1/2 NPT
MaterialAlloy C-276
Power Supply10.5 to 42 V DC (HART)
Stability±0.1% of URL per 5 years
Enclosure RatingNEMA 4X, IP66
Electrical Connection1/2-14 NPT, M20 x 1.5
Response Time100 ms

Summary

Wireless Considerations

Power Up Sequence

Describes the correct sequence for powering up wireless devices with the gateway.

Antenna Position

Guidance on optimal placement of the antenna for clear communication.

Field Communicator Connections

Details on connecting a Field Communicator for transmitter interface.

Mounting the Transmitter

Liquid Flow Application Mounting

Instructions for mounting the transmitter in liquid flow applications.

Gas Flow Application Mounting

Instructions for mounting the transmitter in gas flow applications.

Steam Flow Application Mounting

Instructions for mounting the transmitter in steam flow applications.

Bolting Considerations for Mounting

Guidelines for proper bolting to ensure a tight seal during installation.

O-rings with Flange Adapters

Proper installation and handling of O-rings for flange adapters to prevent leaks.

High Gain, Remote Antenna Installation

Optional installation of a high gain, remote antenna for improved wireless performance.

Connect the Power Module

Transmitter Configuration and Setup

Zero Trim Procedure

Procedure for zero trimming to compensate for mounting position and line pressure effects.

Close the Housing

Instructions for properly closing and sealing the transmitter housing.

Operation Verification

Local Display (LCD) Verification

How to check device status and output values on the local LCD display.

Field Communicator Verification

Verifying operation using a Field Communicator.

Smart Wireless Gateway Verification

Checking device status via the Gateway's web interface.

AMS Wireless Configurator Verification

Using the AMS Wireless Configurator to verify device status.

Troubleshooting Connection Issues

Guidance on resolving issues if the device does not join the network.

Reference Information

Product Certifications

European Directive Information

Details on conformity with European Union directives.

Telecommunication Compliance

Information regarding wireless RF spectrum regulations and certification.

FCC and IC Compliance

Compliance statements for FCC and Industry Canada regulations.

Ordinary Location Certification

Standard certification for ordinary location requirements.

North America Installation Requirements

Notes on NEC and CEC requirements for installation.

USA Safety Certifications

Specific safety certifications and standards for the USA.

Canada Safety Certifications

Specific safety certifications and standards for Canada.

Europe Safety Certifications

Specific safety certifications and standards for Europe (ATEX).

International Safety Certifications

Specific safety certifications and standards for international regions.

Brazil Safety Certifications

Specific safety certifications and standards for Brazil (INMETRO).

China Safety Certifications

Specific safety certifications and standards for China.

Japan Safety Certifications

Specific safety certifications and standards for Japan (TIIS).

EAC Region Safety Certifications

Specific safety certifications for EAC region (Belarus, Kazakhstan, Russia).

Republic of Korea Safety Certifications

Specific safety certifications for the Republic of Korea.

Combined Certifications Information

Information on combined certifications.

Related product manuals