Do you have a question about the Rosemount 3152 and is the answer not in the manual?
Product Type | Pressure Transmitter |
---|---|
Manufacturer | Emerson |
Measurement Type | Pressure |
Display | Optional LCD |
Output Signal | 4-20 mA |
Temperature Range | -40 to 85 °C |
Process Connection | 1/2 NPT |
Electrical Connection | 1/2" NPT conduit |
Housing Material | Stainless steel |
Details standards the transmitters are designed for and requirements for maintaining qualified status.
Steps for mechanical transmitter mounting, conduit installation, and electrical connections for the Rosemount 3150 Series.
Step-by-step instructions for performing span and zero adjustments, including zero-based and elevated/suppressed zero calibrations.
Details the systematic span shift in Ranges 4 and 5 due to high static line pressure and how to correct it.
Provides Method 1 for adjusting transmitter output based on calculated corrected readings for high static line pressure.
Provides Method 2 for adjusting transmitter pressure input based on corrected readings for high static line pressure.
Explains the operation of the 3150 series pressure transmitter using a block diagram and formulas.
Procedure for checking and replacing the electronics assembly if defective.
Steps for checking the sensor module for defects and replacing it if necessary.
Detailed steps for disassembling and reassembling the Rosemount 3150 transmitter, including flange and housing.
Guide to diagnose and correct common symptoms like high output, low output, or erratic output.