www.rosemount.com
¢00825-0100-4725.¤
Quick Installation Guide
00825-0100-4663, Rev BC
December 2012
Rosemount 8732
Start
Step 1: Pre-Installation
Step 2: Handling
Step 3: Mounting
Step 4: Installation
(Flanged Sensors)
(Wafer Sensors)
(Sanitary Sensors)
Step 5: Grounding
Step 6: Wiring
Step 7: Basic Configuration
Product Certifications
End
Rosemount 8732E Magnetic Flowmeter System with
F
OUNDATION
fieldbus (Transmitter and Sensor)
4663RevBCQIG.fm Page 1 Thursday, January 10, 2013 5:33 PM
Question and Answer IconNeed help?

Do you have a question about the Rosemount 8732E and is the answer not in the manual?

Rosemount 8732E Specifications

General IconGeneral
TypeMagnetic Flowmeter Transmitter
CategoryFlow Measurement
ManufacturerEmerson
EnclosureAluminum or Stainless Steel
Communication ProtocolsHART, FOUNDATION Fieldbus
Power Supply12-42 VDC
Enclosure RatingNEMA 4X, IP66/IP67
DisplayBacklit LCD
Product TypeTransmitter
DiagnosticsAdvanced Diagnostics
InputFlow sensor input
OutputHART, FOUNDATION Fieldbus
Hazardous Area ApprovalsATEX, IECEx, FM, CSA
Measurement TypeVolumetric flow
Output Signal4-20 mA
Process ConnectionFlanged, wafer, or sanitary
Electrode Material316L stainless steel, Hastelloy C, titanium, tantalum
Liner MaterialPTFE, PFA, Polyurethane

Summary

PRE-INSTALLATION

Mechanical Considerations

Details on mounting site requirements for the transmitter, ensuring adequate space and access.

HANDLING

MOUNTING

Upstream/Downstream Piping Requirements

Specifies minimum straight pipe diameters required upstream and downstream of the sensor.

Flow Direction Mounting

Instructions on orienting the sensor to point in the direction of flow.

INSTALLATION

Flanged Sensor Installation

Details on gasket selection, flange bolt tightening sequence, and torque values for flanged sensors.

Wafer Sensor Installation

Guidelines for installing wafer sensors, including gasket, alignment spacer, and stud specifications.

Sanitary Sensor Installation

Information on gaskets and alignment/bolting procedures for sanitary sensor installations.

GROUNDING

Process Grounding Options

Table and figures detailing grounding methods based on pipe type and grounding options.

WIRING

Conduit Ports and Cable Requirements

Covers conduit entries, cable types, and preparation for electrical connections.

Transmitter to Sensor Wiring

Details on remote mount cable lengths, preparation, and shielding for transmitter-sensor connections.

FOUNDATION Fieldbus Wiring

Information on fieldbus connection wiring, power supply requirements, and cable specifications.

Transmitter Power Supply Connections

Explains power supply types (AC/DC), wire requirements, disconnects, and overcurrent protection.

BASIC CONFIGURATION

Quick Start-Up and Device Configuration

Overview of initial transmitter configuration, including engineering units and sensor size.

Assigning Device Tag and Node Address

How to assign or change the device tag and network address using a configuration tool.

Flow-Specific Block Configuration

Configuring Analog Input (AI) and Transducer blocks for flow measurement parameters.

Product Certifications

European Directive Information and CE Marking

Details on EC conformity, CE marking, and essential health and safety requirements.

International Certifications and C-Tick Marking

Information on international certifications like IEC and C-Tick marking for product compliance.