Step 1: Mount the Transmitter Head/Probe
Step 2: Set Jumpers and Switches
Step 3: Connect the Wiring
Step 4: Configure
Environmental Conditions
Product Certifications
Start
End
Check Process Connections
Confirm Configuration
www.rosemount.com
Quick Installation Guide
00825-0100-4811, Rev GA
October 2011
Rosemount 3300 Series
Guided Wave Radar Level and Interface
Transmitter

Other manuals for Rosemount 3300 Series

Question and Answer IconNeed help?

Do you have a question about the Rosemount 3300 Series and is the answer not in the manual?

Rosemount 3300 Series Specifications

General IconGeneral
CategoryTransmitter
TypeLevel Transmitter
Model3300 Series
Communication ProtocolHART
Output Signal4-20 mA
Operating Temperature-40 to 85 °C
Process PressureUp to 40 bar
Process ConnectionThreaded, Flanged
MountingTop-mounted
Enclosure RatingIP66
Material316L SST

Summary

Step 1: Mount Transmitter Head/Probe

Step 2: Set Jumpers and Switches

Circuit Board Jumpers and Switches

How to set alarm and write protection jumpers on the circuit board.

LCD Display Settings

How to set alarm and write protection using the LCD display.

Step 3: Connect Wiring

Transmitter Wiring Procedure

Steps to connect wiring to the transmitter, including grounding and power.

Step 3: HART Wiring

HART Output Wiring

Wiring diagrams for HART output, including intrinsic safety connections.

Intrinsically Safe HART Wiring

Specific wiring for Intrinsically Safe HART output connections.

Step 3: Modbus Wiring

Non-intrinsically Safe Modbus Output Wiring

Wiring diagram for Non-intrinsically Safe Modbus output.

Step 4: Configure Transmitter

Radar Configuration Tools (RCT) Software

Instructions for installing and starting the RCT software for configuration.

Environmental Conditions

Product Certifications

Hazardous Location Approvals

ATEX Approval

Details Flameproof (E1) and intrinsic safety conditions for ATEX.

ATEX Flameproof Temperature Limits

ATEX Intrinsic Safety Approvals

BASEEFA Intrinsic Safety

Details intrinsic safety parameters and conditions for BASEEFA ATEX approval.

ATEX Type n Approvals

INMETRO Approvals

NEPSI Approvals

FM Approval

FM Explosion-proof and IS

Covers Factory Mutual approvals for explosion-proof and intrinsically safe use.

IECEx Approval

IECEx Flameproof and IS

Outlines IECEx approvals for flameproof and intrinsic safety certifications.

Related product manuals