Reference Manual
00809-0100-4809, Rev DA
Appendix A: Specifications and Reference Data
September 2015
138
Specifications and Reference Data
Temperature measurement
R Remote thermowell and RTD
Transmitter connection platform
3 Direct-mount, Integral 3-valve Manifold– not available with flanged model greater than class 600 ★
5 Direct -mount, 5-valve Manifold – not available with flanged model greater than class 600 ★
7 Remote-mount NPT connections (
1
/2-in. FNPT) ★
8 Remote-mount SW Connections (
1
/2-in.)
Differential pressure range
1 0 to 25 inH
2
O (0 to 62,3 mbar) ★
2 0 to 250 inH
2
O (0 to 623 mbar) ★
3 0 to 1000 inH
2
O (0 to 2,5 bar) ★
Transmitter output
A
(3)
4–20 mA with digital signal based on HART Protocol ★
F FOUNDATION Fieldbus Protocol ★
W PROFIBUS PA Protocol ★
X Wireless ★
M Low-Power, 1-5 Vdc with digital signal based on HART Protocol
Transmitter housing material Conduit entry size
A Aluminum
1
/2-14 NPT ★
B Aluminum M20 ⫻ 1.5 ★
J SST
1
/2-14 NPT ★
K
(4)
SST M20 ⫻ 1.5 ★
P
(5)
Engineered Polymer No conduit entries ★
D Aluminum G
1
/2
M
(4)
SST G
1
/2
Transmitter performance class
1 2.3% flow rate accuracy, 5:1 flow turndown, 2-year stability ★
Wireless options (requires wireless output code X and Engineered Polymer housing code P)
Wireless transmit rate, operating frequency, and protocol
WA3 User configurable transmit rate, 2.4GHz WirelessHART ★
Antenna and SmartPower
WP5 Internal antenna, compatible with Green Power Module (I.S. Power Module sold separately) ★
Table 11. Rosemount 2051CFA Annubar Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.