Reference Manual
00809-0100-4803, Rev GA
September 2017
Rosemount
3051S MultiVariable
Transmitter

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Rosemount 3051S and is the answer not in the manual?

Rosemount 3051S Specifications

General IconGeneral
TypePressure Transmitter
Accuracy±0.025% of span
Output4-20 mA with HART, FOUNDATION Fieldbus, PROFIBUS PA
Process Connection1/4 NPT, 1/2 NPT
Temperature Range-40 to 85°C (-40 to 185°F)
Material316L stainless steel, Hastelloy C-276
Enclosure RatingNEMA 4X, IP66
Measurement TypeAbsolute, Gauge, Differential Pressure, Level
DiagnosticsAdvanced diagnostics
Certifications/ApprovalsATEX, IECEx, FM, CSA
Power Supply10.5 to 42 VDC
Response Time100 ms

Summary

Section 2 Configuration

2.2 Safety messages

Provides critical safety precautions to be followed before performing any configuration operations.

2.4 Flow configuration

Guides the user through setting up flow configuration using the Engineering Assistant software.

2.5 Basic device configuration

Covers the essential procedures for commissioning the Rosemount 3051SMV, including basic setup.

2.6 Detailed device configuration

Explains how to configure detailed device parameters like identification, alarms, mapping, and communication.

2.7 Variable configuration

Details how to configure specific process variables such as flow rate, energy rate, totalizer, and pressure.

Section 3 Installation

3.2 Safety messages

Highlights essential safety precautions required during the installation process.

3.4 Installation procedures

Outlines the step-by-step procedures for installing the transmitter, including security and alarm configuration.

Section 4 Operation and Maintenance

4.2 Safety messages

Provides critical safety warnings relevant to operation and maintenance tasks.

4.3 Transmitter calibration

Details the tasks involved in configuring output parameters and calibrating sensors and analog output.

4.4 Transmitter functional tests

Explains how to perform functional tests for flow/energy calculations and analog output loop tests.

Section 5 Troubleshooting

5.4 Engineering Assistant communication troubleshooting

Provides corrective actions for common communication issues between Engineering Assistant and the transmitter.

5.5 Measurement troubleshooting

Addresses unexpected process variable readings and their potential causes and solutions.

5.2 Device diagnostics

Explains how to interpret HART host and LCD display diagnostic alerts for troubleshooting.

5.3 Measurement quality and limit status

Details how to interpret measurement quality and limit statuses for diagnosing issues.

Section 6 Safety Instrumented Systems Requirements

6.4 Configuring in SIS applications

Details configuration steps for the transmitter when used in SIS applications, including damping and alarms.

Appendix A Specifications and Reference Data

A.1.1 Performance specifications

Lists performance specifications including reference accuracy, DP ranges, and temperature interface accuracy.

Related product manuals