Specifications and Reference Data
September 2017
Reference Manual
00809-0100-4803, Rev GA
Specifications and Reference Data
138
A.3 Ordering information
A.3.1 Rosemount 3051S MultiVariable Transmitter
Table A-6. Rosemount 3051S Scalable MultiVariable Transmitter Ordering Information
The starred offerings (★) represent the most common options and should be selected for best delivery. The non-starred offerings are subject to
additional delivery lead time.
Rosemount
model
Transmitter type
3051SMV Scalable MultiVariable Transmitter
Performance class
Rosemount 3051SMV multivariable SuperModule, measurement types 1 and 2
3
(1)
Ultra for Flow: 0.04% reading DP accuracy, 200:1 rangedown,15-year stability, 12-year limited warranty ★
5 Classic MV: 0.04% span DP accuracy, 100:1 rangedown, 15-year stability ★
Rosemount 3051SMV single variable SuperModule, measurement types 3 and 4
1
(2)
Ultra: 0.025% span DP accuracy, 200:1 rangedown, 10-year stability, 12-year limited warranty ★
2 Classic: 0.055% span DP accuracy, 100:1 rangedown, 5-year stability ★
3
(1)
Ultra for Flow: 0.04% reading DP accuracy, 200:1 rangedown,10-year stability, 12-year limited warranty ★
Multivariable type
M Multivariable measurement with fully compensated mass and energy flow ★
P Multivariable measurement with direct process variable output ★
Measurement type
1 Differential pressure, static pressure, and temperature ★
2 Differential pressure and static pressure ★
3 Differential pressure and temperature ★
4 Differential pressure ★
Differential pressure range
0
(2)(3)
–3 to 3 inH
2
O (–7,47 to 7,47 mbar) ★
1 –25 to 25 inH
2
O (–62,2 to 62,2 mbar) ★
2 –250 to 250 inH
2
O (–623 to 623 mbar) ★
3 –1000 to 1000 inH
2
O (–2,5 to 2,5 bar) ★
4 –300 to 300 psi (–20,7 to 20,7 bar) ★
5 –2000 to 2000 psi (–137,9 to 137,9 bar) ★
Static pressure type
N
(4)
None ★
A Absolute ★
G Gage ★
Static pressure range Absolute Gage
N
(4)
None N/A N/A ★
3 Range 3 0.5 to 800 psia (0,03 to 55,2 bar) –14.2 to 800 psig (–0,98 to 55,2 bar) ★
4
(5)
Range 4 0.5 to 3626 psia (0,03 to 250 bar) –14.2 to 3626 psig (–0,98 to 250 bar) ★
Temperature input
N
(6)
None ★
R
(7)
RTD input (type Pt 100, –328 to 1562 °F [–200 to 850 °C]) ★

Table of Contents