Loading...
Reference Manual
00809-0100-4809, Rev DA
Appendix A: Specifications and Reference Data
September 2015
89
Specifications and Reference Data
Line size D 1-7
420 42-in. (1066 mm)
480 48-in. (1210 mm)
600 60-in. (1520 mm)
720 72-in. (1820 mm)
780 78-in (1950 mm)
840 84-in. (2100 mm)
900 90-in. (2250 mm)
960 96-in. (2400 mm)
Pipe I.D. range
(1)
C Range C from the Pipe I.D. table
D Range D from the Pipe I.D. table
A Range A from the Pipe I.D. table
B Range B from the Pipe I.D. table
E Range E from the Pipe I.D. table
Z Non-standard Pipe I.D. range or line sizes greater than 12-in. (300 mm)
Pipe material/Mounting assembly material
C Carbon steel (A105)
S 316 Stainless Steel
0
(2)
No mounting (customer supplied)
G Chrome-Moly Grade F-11
N Chrome-Moly Grade F-22
J Chrome-Moly Grade F-91
Piping orientation
H Horizontal piping
D Vertical piping with downwards flow
U Vertical piping with upwards flow
Annubar type
P Pak-Lok
Table 1. Rosemount 3051SFA Annubar Flowmeter Ordering Information
The Standard offering represents the most common options. The starred options () should be selected for best delivery.
__The Expanded offering is subject to additional delivery lead time.