Figure 5: Tally Port (female)
Table 29: Tally Rating
ValueSpecification
Solid-State Contact ClosureType
100VDCInput Voltage
120mAMaximum Current
Note: Tally ports 3 through 6 on the control panel are used for
the extended tallies option and require the extended tallies
hardware to be installed before they can be used.
Table 30: Panel Tally Locations
Port 6Port 5Port 4Port 3Port 2Port 1Pin
917355371911
937557392132
957759412353
977961432574
998163452795
10183654729116
10385674931137
10587695133158
10789715335179
Common10
Common11
Common12
Common13
9274563820
214
9476584022415
9678604224616
9880624426817
100826446281018
102846648301219
104866850321420
106887052341621
108907254361822
Common23
Common24
Common25
Contact Closure Ports
The contact closure (CtCl) ports are located at the back
of the frame.
12345678910111213
141516171819202122232425
Figure 6: Contact Closure Port (female)
Table 31: Contact Closure Rating
ValueSpecification
Solid-State Contact ClosureType
100VDCInput Voltage
120mAMaximum Current
Table 32: Contact Closure Locations
Port 1Pin
CtCl 1 Out1
CtCl 2 Out2
CtCl 3 Out3
CtCl 4 Out4
CtCl 5 Out5
CtCl 6 Out6
CtCl 7 Out7
CtCl 8 Out8
CtCl 9 Out9
CtCl 10 Out10
CtCl 11 Out11
CtCl 12 Out12
n/c13
CtCl 1 Common14
CtCl 2 Common15
CtCl 3 Common16
CtCl 4 Common17
CtCl 5 Common18
CtCl 6 Common19
CtCl 7 Common20
CtCl 8 Common21
CtCl 9 Common22
CtCl 10 Common23
CtCl 11 Common24
CtCl 12 Common25
Acuity UHD Configuration Guide (v9.1) Specifications 27