AC-215 Single and Double Door Access Control Unit
Hardware Installation Guide
3
AC-215 Single and Double Door Access
The operation mode is first defined on the 8Way Dip switch on the AC-215 main PCB (the third
switch defines the operation mode as described on page 11 "ACU Type") and then defined as
either single or double door in the AxTraxAS-525 software, both definitions should be
correlate.
Single Door Controller
This access type has two readers, IN or OUT
Outputs: Door lock strike
Auxiliary output
Alarm output
General purpose output
Inputs: Release to exit
Door monitor input
Tamper input
General purpose input
Double Door Controller
This access type has two readers, IN or OUT
Outputs: Door 1 lock strike
Door 1 alarm output
Door 2 lock strike
Door 2 alarm output
Inputs: Release to exit door1
Door 1 monitor input
Release to exit door 2
Door 2 monitor input