EasyManuals Logo

Rosslare AC-215 Hardware Installation Guide

Rosslare AC-215
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
AC-215 Single and Double Door Access Control Unit
Hardware Installation Guide
8
Door Alarm
This output is activated when either an alarm occurs in the system, or automatically by a time
zone. The following should be defined:
Single door controller:
Door 1 OUT1A
Double door controller:
Door 1 OUT1A
Door 2 OUT2A
The output can be activated for a specified time and closes when the timer ends.
Auxiliary
This output is activated when a transaction occurs in the readers that are either associated
with auxiliary, or automatically by a time zone. The following should be defined:
Single door controller:
Door 1 OUT2
The output has two activations modes:
Time active for a specified time and closes when the timer ends
Toggle active for every change in the output trigger - the trigger changes state
General
This output is usually related to the general input or automatically by a time zone.
The following should be defined:
Single door controller:
Door 1 OUT2A
The output has three activation modes:
Follow input output follows the input state
Toggle active for every change in the output trigger - the trigger changes state
Time active for a specified time and closes when the timer ends