8
* Perform check with and without a vehicle representative load.
REPAIR MAINTENANCE
(MAINTENANCE AUTHORIZED BY QUALIFIED SERVICE REPRESENTATIVE ONLY)
• Check accessibility of the operating procedures.
• Check accessibility and readability of all labels.
• Check the rated load capacity of the lift.
• Examine all structural components including welds.
• Check electrical cords for insulation damage.
• Check uid level.
• Check the lift controls for function.
• Check all fastening devices for tightness including oor anchor bolts.
• Check exposed surfaces and edges.
• Operate the lift and check the operation of the positive stop and the lift safety latches.
• With a representative vehicle on the lift, check the lowering speed (not to exceed 0.15 m/s).
• With a representative vehicle on the lift, check cable tension adjustment.
• Check the function of slack cable switches.
• Check all accessible piping, tubing, hose, valves and ttings. Review lift uid consumption records.
• Operate lift through full excursion and observe.
• With lift loaded, stop the lift at midpoint of travel and observe for drifting down and hydraulic leaks.
• Check with operator to ascertain any unusual operating characteristics.
*
Inspection Points
• Lockout any energy sources before beginning
any repairs.
•DONOT modify the lift in any manner without the
prior written consent of the manufacturer.
• If electrical problems develop, make repairs ac-
cording to local electrical codes. Use genuine
Rotary Lift parts when replacement is necessary.
• Replace worn parts as required with genuine
Rotary parts.
• Cable adjustment should be checked by a Rotary
Authorized Installer after the rst 50 loaded lift
cycles and after 300 loaded lift cycles.
• Adjust cable tension per lift installation instruc-
tions.
• Monthly: Lubricate locking latch shafts. Activate
latches several times for oil to penetrate joints.
Aside from the routine checks that are stated under "Operator Maintenance", the following annual inspec-
tion is to be performed and a record of this inspection permanently retained on site. All deficiencies are
to be corrected by the proper authorized personnel.
Annual Inspection
(performed by Authorized Personnel)