10
TROUBLE SHOOTING FOR AUTHORIZED MAINTENANCE PERSONNEL
Cause
1. Incorrectvoltagetomotor.
2. Bad wiring connections.
3. Motorupswitchburnedout.
4. Overheadlimitswitchburnedout.
5. Motorwindingsburnedout.
1. Overloading lift
2. Motorrunningonlowvoltage
3. Debrisinloweringvalve
4. Pumpsuckingair
5. Suctionstuboffpump
6. Low oil level
7. Improperreliefvalveadjustment
1. Debrisincheckvalveseat.
2. Debrisinloweringvalveseat.
3. External oil leaks.
1. Airmixedwithoil.
2. Airmixedwithoilsuction.
3. Oil return tube loose.
1. Equalizercablesoutofadjustment.
2. Liftinstalledonunleveloor.
1. Holesdrilledoversize.
2. Concreteoorthicknessorholding
strengthnotsufcient.
1. Low oil level
2. Air in hydraulic lines/cylinder
1. None
Remedy
1. Supplycorrectvoltagetomotor.
2. Repair and insulate all connections.
3. Replace switch/controls.
4. Replaceoverheadlimitswitch.
5. Replacemotor.
1. Check vehicle weight and/or balance
vehicle weight on lift
2. Supplycorrectvoltagetomotor
3. Clean lowering valve
4. Tightenallsuctionlinettings
5. Replace suction stub
6. Fill tank to proper level with ISOVG32
hydraulicoilorDexronIIIATF
7. Replacereliefvalvecartridge.
1. Clean check valve.
2. Clean lowering valve.
3. Repair external leaks.
1. ChangeoiltoDexronIIIATF
or ISOVG32.
2. Tightenallsuctionlinettings.
3. Reinstall oil return tube.
1. Adjustequalizercablestocorrect
tension.
2. Shimlifttolevelcolumns(Notto
exceed13mm).Ifover13mm,break
outoorandlevelperliftinstallation
instructions.
1. Relocate lift using new bit to drill holes.
Reference installation instructions for
properanchoringmethodandminimum
spacingrequirements.
2. Break out old concrete and re-pour
new pads for lift per lift installation
instruction.
1. FilltanktoMIN___markwith
ISOVG32hydraulicoilorDexronIIIATF.
2.Startunit,raiseliftabout610mm.Open
cylinderbleedersapproximately2
turns.Closebleederswhenuid
streams.Lowerliftandlltank.
1. None,thisisnormal.
Trouble
Motordoesnotrun.
Motorrunsbutwillnotraiselift
Lift slowly settles down.
Slowliftingspeedoroilblowingoutller
breather cap.
Lift going up unlevel.
Anchors will not stay tight.
Lift stops short of full rise or chatters.
Lockinglatchsolenoidsgetextremelyhot
when lift is being lowered.
Note: Shimthicknessof51mmispossiblebyusingoptionalshimkit#FC5393.ContactyourauthorizedRotaryrepairperson.