Effectivity: 447 UL SCDI, 503 UL DCDI, 582 UL DCDI /mod. 99
INSTALLATION MANUAL
AIRCRAFT ENGINES
page 18 - 7
Initial issue, May 01/99
d00328
B
M
E
S
DC
fuse 16A
battery
12V 16 Ah (min.)
starter relay
electric starter
starter
button
consumers
fuse
fig. 46
02829
18.5.4) Electric starter
Two types of electric starters can be fitted to ease starting
procedures especially in flight.
Electric starter fitted on ā€œEā€ type gearbox. There is also the
possibility to use a rewind start.
Electric starter fitted on magneto side. However for use on
engines utilizing a ROTAX gear reduction unit, this electric
starter system prevents rewind starter application.