d07068.fm
08 February 2024 74-20-00
Initial Issue Page 10 of 15
Copyright - BRP-Rotax GmbH & Co KG. All rights reserved.
SI-912 i-029 / SI-915 i-012
SI-916 i-007
SERVICE INSTRUCTION
1 Double ignition coils
2 Ignition coil connector
Fig. 7
3.5.2) Wiring harness - removal
3.5.3) Double ignition coil - inspection
Step Procedure
7 Unplug the connectors to the double ignition coils. See current Maintenance Manual
Heavy (MMH), Chapter 76-50-00 Wiring harness - removal.
8 Remove the double ignition coils.
See current Maintenance Manual Heavy (MMH) for the respective engine type, Chapter
76-50-00 Wiring harness - removal.
Carry out a visual inspection. See current Maintenance Manual Line (MML) for the re-
spective engine type, Chapter 05-20-00 section Visual inspection.
Step Procedure
1 Carry out a visual inspection, check double ignition coils for damage, corrosion, and
deformation
2 Carry out a resistance test. To do this, see current Maintenance Manual Heavy (MMH),
Chapter 76-70-00 section Sensors and actuators.