d07068.fm
SI-912 i-029 / SI-915 i-012
SI-916 i-007
SERVICE INSTRUCTION
08 February 2024 74-20-00
Initial Issue Page 11 of 15
Copyright - BRP-Rotax GmbH & Co KG. All rights reserved.
3.5.4) Double ignition coil - installation
1 Protection hose
2 Ignition cable
3 Protective cap
4 Threaded prong
Fig. 8
Double ignition coil
Measurement
Figure
Measuring points Resistance
Primary side 0.5 Ω +/- 0.5 Ω
Secondary side 9 kΩ +/- 0.9 kΩ
Between primary
and secondary side
Infinite
See current Maintenance Manual Heavy (MMH) for the respective engine type, Chapter
74-20-00.
Step Procedure
1 Screw ignition cable clockwise into coil.
2 Slide rubber seal over coil.
3 Place the appropriately marked protection hose over the ignition cable.