d07068.fm
SI-912 i-029 / SI-915 i-012
SI-916 i-007
SERVICE INSTRUCTION
08 February 2024 74-20-00
Initial Issue Page 13 of 15
Copyright - BRP-Rotax GmbH & Co KG. All rights reserved.
1 Allen screw M5x20
2 Lock washer A5
3 Connector bracket
4 Cable clamp 8/M5
Fig. 10
1 Exhaust Gas Temperature Sensor (EGT)
2 Connector bracket
3 Connector
Fig. 11
Step Procedure
7 Install the exhaust gas temperature sensors (cylinder 1 and cylinder 2) with the spring
hook onto the connector bracket and push until it snaps into place.
8 Connect the Exhaust Gas Temperature sensors. See current Maintenance Manual
Heavy (MMH), Chapter 76-50-00, section Exhaust Gas Temperature Sensor (EGT) -
connection.