EasyManua.ls Logo

Rotax 912 i series - Page 14

Rotax 912 i series
15 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
d07068.fm
08 February 2024 74-20-00
Initial Issue Page 14 of 15
Copyright - BRP-Rotax GmbH & Co KG. All rights reserved.
SI-912 i-029 / SI-915 i-012
SI-916 i-007
SERVICE INSTRUCTION
1 Allen screw M6x14
2 Lock washer A6
3 Cable clamp 12/M6
Fig. 12
1 EGT sensor cable
2 Double ignition coil cable
3 Cable tie
Fig. 13
Step Procedure
9 Secure the cable clamp 12/M6 with an Allen screw M6x14 and lock washer with
LOCTITE 243. Tightening torque 10 Nm (89 in. lb).
Step Procedure
10 Install the cable tie on the exhaust gas temperature sensor cable (Cyl. 1_3) connected
with the double ignition coil cable.

Other manuals for Rotax 912 i series

Related product manuals