Effectivity: 914 Series BRP-Powertrain page 3-8
OM Edition 2 / Rev. 0 April 01/2010
d04475.fm
To observe! Reduction gear with shock absorber
9 Oil pressure Check if oil pressure has ri-
sen within 10 seconds and
monitor oil pressure. Increa-
se of engine speed is only
permitted at steady oil pres-
sure readings above 2 bar
(30 psi).
10 At an engine start with low oil tempera-
ture, continue to observe the oil pres-
sure as it could drop again due to the
increased flow resistance in the suction
line. The engine speed rpm may be only
so far increased that the oil pressure re-
mains steady.
11 Staring carb De-activate.
Step Designation Procedure
NOTICE
NOTICE
Since the engine comprises a reduction gear
with shock absorber, take special care of the
following:
Step Procedure
1
To prevent impact load, start with throttle lever in idle
position or at the most up to 10% open.
2
For the same reason, wait for around 3 sec. after
throttling back to partial load to reach constant speed
before re-acceleration.
3
For checking the two ignition circuits, only one circuit
may be switched off and on at a time.

Table of Contents

Other manuals for Rotax 914 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rotax 914 series and is the answer not in the manual?

Rotax 914 series Specifications

General IconGeneral
Bore79.5 mm
Stroke61 mm
Compression Ratio9.0:1
Cooling SystemLiquid-cooled cylinder heads, air-cooled cylinders
Redline5800 rpm
Engine Type4-cylinder, 4-stroke
Fuel TypeAvgas 100LL
Oil SystemDry sump
Fuel Systemfuel injection
TBO (Time Between Overhauls)2000 hours
Displacement1.211 liters (1211 cc)
Power Output84.6 kW (115 hp) at 5, 800 rpm