39User manual
Room air conditioner - TETA X
EN
PART 2. CLEANING AND MAINTENANCE
3. CLEAN THE FILTER
TIP: When you nd accumulated dust in the lter, please clean the lter in time to ensure the clean, healthy
and ecient operation inside the air conditioner.
Take out the lter
from the unit
Clean the lter with
soapy water and air dry it
Replace the lter
4. CLEANING OF INNER AIR DUCT
First, loosen the knob on the middle of louver and bend the louver outwards to take it out.
Then, grasp both sides of bottom plate push downwards to take down the bottom plate.
Finally, loosen the buckle of deector assembly with your thumb and take it out. Wipe the air duct and
fan assembly with a clean and wrung wet rag.
Clean the removed parts with soapy water and air dry it. After cleaning, restore the removed parts in turn.
Louver
Deector assembly
Bottom plate
5. SERVICE AND MAINTENANCE
When the air conditioner is not in use for a long time, do the following work:
Take out the batteries of the remote controller and disconnect the power supply of the air conditioner.
When starting to use after long-term shutdown:
1. Clean the unit and lter screen;
2. Check whether there are obstacles at the air inlet and outlet of indoor and outdoor units;
3. Check whether the drain pipe is unobstructed;
Install the batteries of the remote controller and check whether the power is on.