7 x Hydraulic connection
51
FA ROTEX A1 BO - 10/2007
Thermal output data Hot water storage tank
Tab. 7-2 Thermal output data of the ROTEX hot water storage tank which can be connected to the oil condensing boiler
*T
KW
= Cold water temperature
T
WW
= Hot water temperature
T
SP
= Storage temperature
T
V
= Feed temperature
The plastic gravity brakes recommended as an accessory ( 16 50 70) in the pipe connections are suitable
for temperatures up to max. 90°C.
Type Sanicube INOX Sanicube INOX Sanicube
Solaris INOX
Sanicube
Solaris PEX
Sub-tank for
hot water
storage tank
Parameter SCS 328/16/0 SC 538/16/0 SCS 538/16/0 SCS 580/1 US 150
Efficiency characteristic N
L
according to DIN 4708
(on recharging at 35 kW,
T
KW
=1C / T
WW
=4C / T
SP
=6C /
T
v
=8C):
2.2 4.1 2.3 3.5 2.2
Continuous output Q
D
according to DIN 4708 27 kW 35 kW 35 kW 35 kW 25 kW
Maximum draw-off rate for the duration of 10 min
on recharging at 35 kW
(T
KW
=1C / T
WW
=4C / T
SP
=6C)
21 l/min 30 l/min 22 l/min 25 l/min 16 l/min
Hot water quantity without reheating with up to
15 l/min draw-off rate
(T
KW
=1C / T
WW
=4C / T
SP
=6C)
200 Litres 412 Litres 220 Litres 335 Litres 250 Litres
Hot water quantity with reheating at
20 kW reheating power and 15 l/min draw-off rate
(T
KW
=1C / T
WW
=4C / T
SP
=6C)
400 Litres 837 Litres 442 Litres 600 Litres 300 Litres
Short-term water quantity in 10 min 210 Litres 300 Litres 220 Litres 250 Litres 160 Litres