1 x Safety
7
FA ROTEX A1 BO - 10/2007
1.5 Instructions for operating safety
Before working on the heating system
Only authorised and trained heating engineers should work on the heating system (e.g. set-up, connection and initial start-up).
Switch off the mains supply before starting any work on the heating system and secure it against unintentional switch-on.
Electrical installation
Electrical installations may only be carried out by qualified electrical technicians under observance of the relevant electrical
guidelines and the regulations of the electric utilities company.
Compare the mains voltage (230 V, 50 Hz) indicated on the nameplate with the supply voltage before connecting to the mains.
Unit installation room
Operate the oil condensing boiler only if sufficient combustible air supply is guaranteed. If operating the oil condensing boiler
independently of the ambient air with an air/flue system (LAS) with dimensions according to ROTEX-Standard, this is
automatically guaranteed and there will be no further conditions required of the unit installation room.
Make sure that there is a supply air opening to the open air, of at least 150 cm
2
with ambient air dependent operation.
Do not operate the oil condensing boiler dependent on ambient air in rooms with aggressive vapours (e.g. hair spray, perchlo-
roethylene, carbon tetrachloride), strong dust formation (e.g. workshop) or high atmospheric humidity (e.g. laundry).
Strictly keep the minimum distances to walls and other objects (see chapter 3.1).
Heating system
Create a heating system according to the safety requirements of EN 12828, as an open or closed heating system.
Note that the safety valves must comply with DIN EN ISO 4126-1 and be type tested. The safety valves must be installed
in the safety flow.
Check the correct installation of the temperature sensor and safety temperature controller before the initial start up.
Always operate the oil condensing boiler with the sound insulation hoods closed.
Fuel
Use only the approved heating oils as fuel (see chapter 11 "Technical data").
Instructing the user/owner
Before you hand over the heating system, explain to the owner how he/she can operate and check the heating system.
Make a record of the handover by filling out and signing the installation and instruction forms jointly with the user/owner.