Threshold Limit 2
This parameter is used to set threshold 2 for the deviation in Load for Opening of current
value from the reference value.
• Off
This parameter value does not trigger any message or alarm.
• Custom
This parameter is used to set the threshold 2 in bars.
The device triggers a fault message if the difference between the current value and the
reference value exceeds threshold 2. The value can be set from 0.0 to 10.0 bars.
Threshold Limit 3
This parameter is used to set threshold 3 for the deviation in Load for Opening of current
value from the reference value.
• Off
This parameter value does not trigger any message or alarm.
• Custom
This parameter is used to set the threshold 3 in bars.
The device triggers a fault message if the difference between the current value and the
reference value exceeds threshold 3. The value can be set from 0.0 to 10.0 bars.
Valve Position Statistics
Applicable for Posidapt –Super and Ultra
Hours in Temperature Ranges
This value displays the statistics about the duration of operation in different temperatures
range. The number of the operating hours is recorded in the corresponding temperature
range. The following are the temperature range.