6 Installation related setting
00 Installation related setting
01 Installation related setting
02 Not applicable. Do not change the default value. — — — —
Scheduled storage and reheat domestic water heating
03 Scheduled time storage 1 (ON) 0/1 1 —
04 Scheduled time storage start time 1:00 0:00~23:00 1:00 hour
05 Scheduled time reheat or continuous reheat 0 (OFF) 0/1/2 1 —
06 Scheduled time reheat start time 15:00 0:00~23:00 1:00 hour
07 Domestic hot water reheat set point 45 30~50 1 °C
08 Domestic hot water reheat set point hysteresis 10 2~20 1 °C
7 Installation related setting
00 Installation related setting
01 Installation related setting
02 Installation related setting
03 Installation related setting
04 Installation related setting
8 Installation related setting
00 Installation related setting
01 Installation related setting
02 Installation related setting
03 Installation related setting
04 Installation related setting
9 Heating and cooling set point ranges
00 Heating set point upper limit 55 37~55 1 °C
01 Heating set point lower limit 25 15~37 1 °C
02 Cooling set point upper limit 22 18~22 1 °C
03 Cooling set point lower limit 5 5~18 1 °C
04 Installation related setting
Automatic set back function
05 Set back operation 0 (OFF) 0/1 1 —
06 Set back operation start time 23:00 0:00~23:00 1:00 hour
07 Set back operation stop time 5:00 0:00~23:00 1:00 hour
08 Leaving water set back value 2 0~10 1 °C
A Quiet mode
00 Quiet mode type 0 0/2 — —
01 Status 3———
02 Not applicable. Do not change the default value. 1
(a)
Read only — —
03 Not applicable. Do not change the default value. 0
(a)
Read only — —
04 Not applicable. Do not change the default value. 0
(a)
Read only — —
b Not applicable
00 Not applicable. Do not change the default value. 0
(a)
Read only — —
01 Not applicable. Do not change the default value. 0
(a)
Read only — —
02 Not applicable. Do not change the default value. 0
(a)
Read only — —
03 Not applicable. Do not change the default value. 0
(a)
Read only — —
04 Not applicable. Do not change the default value. 0
(a)
Read only — —
First
code
Second
code
Setting name
Installer setting at variance with default value
Default
value
Range Step UnitDate Value Date Value