INSTALLATIONSANLEITUNG
Installationsanleitung
Inneneinheit für Luft-Wasser-Wärmepumpensystem
Deutsch
Installation manual
Indoor unit for air to water heat pump system
English
Manuale d'installazione
Unità interna per sistema a pompe di calore aria acqua
Italiano
Inneneinheit für
Luft-Wasser-Wärmepumpensystem
RKHBH008BB3V3
RKHBH008BB6V3
RKHBH008BB6WN
RKHBH008BB9WN
RKHBX008BB3V3
RKHBX008BB6V3
RKHBX008BB6WN
RKHBX008BB9WN
Manuel d'installation
Unité intérieure pour système de pompe à chaleur air à eau
Français
Montagehandleiding
Binnenunit voor lucht-water-warmtepompsysteem
Nederlands
Manual de instalación
Unidad interior para sistema de bomba de calor de aire-agua
Español
Manual de instalação
Unidade de interior para o sistema de bomba de calor ar/água
Portugues
Montaj kılavuzu
Havadan suya ısı pompası sistemi için iç ünite
Türkçe
Manual de instalare
Unitate interioară pentru sistem de pompă termică aer la apă
română
Instalační návod
Vnitřní jednotka pro systém tepelných čerpadel vzduch-voda
čeština

Table of Contents

Questions and Answers

  • K
    Keith EvansAug 11, 2025
    What to do if the compressor is not starting on my Rotex RKHBH008BB3V3 Heat Pump?
    • A
      Andrea HuntAug 11, 2025
      If your Rotex Heat Pump unit is on but the compressor isn't starting for space or domestic water heating, it could be due to a low water temperature. The system uses a backup heater to reach the minimum water temperature (15°C). Check that the backup heater power supply is correct, the thermal fuse is closed, the thermal protector isn't activated, and the contactors aren't broken.
  • T
    Tanya NewmanAug 17, 2025
    Why is the Rotex Heat Pump not heating properly despite being turned on?
    • B
      bvelezAug 17, 2025
      If your Rotex Heat Pump is on but not heating or cooling as expected, the water flow might be too low. To resolve this: * Ensure all shut-off valves in the water circuit are fully open. * Check and clean the water filter if necessary. * Purge any air from the system. * Verify sufficient water pressure (above 1 bar when the water is cold). * Set the pump speed to the highest setting. * Check the expansion vessel is in working order. * Ensure the resistance in the water circuit isn't too high for the pump.
  • L
    Lori GonzalezAug 22, 2025
    What to do if my Rotex RKHBH008BB3V3 is not heating and the water volume is low?
    • W
      wilsonmollyAug 23, 2025
      If your Rotex Heat Pump is on but not heating or cooling as expected, the water volume in the installation might be too low. Ensure that the water volume is above the minimum required value.
  • H
    Holly MyersAug 28, 2025
    Why isn't the compressor starting on my Rotex RKHBH008BB3V3 Heat Pump after turning it on?
    • J
      Jerome BerryAug 28, 2025
      If your Rotex Heat Pump unit is on but the compressor isn't starting for space or domestic water heating, the benefit kWh rate power supply settings and electrical connections may not match. If [d-01]=1 or 2, the wiring requires specific installation. Other correctly installed configurations are possible, but are to be specific for the type of benefit kWh rate power supply type at this specific site.
  • M
    Maria RichardsonSep 3, 2025
    What does it mean when the compressor on my Rotex Heat Pump won't start?
    • C
      Cole LamSep 4, 2025
      If your Rotex Heat Pump unit is on but the compressor isn't starting for space or domestic water heating, it may be because the benefit kWh rate signal was sent by the electricity company. Wait for the power to return.

Rotex RKHBH008BB3V3 Specifications

General IconGeneral
BrandRotex
ModelRKHBH008BB3V3
CategoryHeat Pump
LanguageEnglish