4 x Start-up and taking out of service
27
FA ROTEX Solaris RPS3 P2 - 06/2012
4.2 Taking out of service
4.2.1 Temporary shutdown
If solar support is not needed for the water heater for a longer period of time, the solar system can be switched off temporarily
from the mains switch of the Solaris RPS3 P2 control and pump unit.
If there is any danger of frost in the area of the storage tank circuit do the following:
start the solar system in operation
or
suitable antifreeze measures must be applied to the connected heating system and hot water storage tank (e.g. draining).
Draindomestic hot water storage tank
Switch off the main switch and secure against restarting.
Connect the hose to the solar return flow of the hot water storage tank with the KFE cock (accessory 16 41 17) using
the hose connection.
Drain the tank's water content.
4.2.2 Permanent decommissioning
Taking the Solaris RPS3 P2 control and pump unit out of service (see chapter 4.2.1 "Temporary shutdown").
Disconnect the Solaris RPS3 P2 control and pump unit from all electrical connections and hydraulic connections.
Uninstall the Solaris RPS3 P2 control and pump unit as shown in the installation instructions (chapter 3 "Installation") but
in the reverse order.
Dispose of the Solaris RPS3 P2 control and pump unit correctly.
Notes on disposal
CAUTION!
A heating system which is shut down can freeze in the event of frost and may suffer damage.
Drain the heating system that is shut down if there is danger of frost.
If there is a danger of frost for just a few days, the unit's excellent heat insulation means that the insulated tank
does not have to be drained, provided that the storage tank temperature is monitored regularly and does not fall
below +3 °C. This does not, however, provide any protection against frost for the connected heat distribution
system!
Due to the environmentally-friendly design of the Solaris system, ROTEX has complied with the requirements for
environmentally-responsible disposal. During the disposal process, the only waste accrued is that which can be
used for material or thermal recycling.
The materials used that are suitable for recycling can be sorted into individual types.
The designation of the product means that electrical and electronic products may not be disposed of together
with unsorted domestic waste.
Proper disposal in compliance with the respective national regulations of the country of use is the responsibility
of the user/owner.
Disassembly of the system, handling of coolant, oil and other parts may only be carried out by a qualified
fitter.
Disposal may only be carried out by a facility that specialises in reuse, recycling and recovery.
Further information is available from the installation company or the responsible local authorities.