Do you have a question about the rotork CML-750 and is the answer not in the manual?
ATEX and IECEx certifications for hazardous areas, including flamepath ratings and temperature limits.
Critical flamepath dimensions for ATEX and IECEx approved actuators.
Covers electrical hazards, ESD, enclosure materials, hand operation, local controls, and reserve power pack safety.
Steps for commissioning the actuator, including tools, valve position, and setup steps.
Detailed instructions for installing the actuator, including safety guidelines and handwheel operation.
Details on optional local controls, selector operation, and external LCD display.
Explanation of the Reserve Powerpack function for operation during power failure.
Procedure for mounting the CML linear actuator to the valve, emphasizing correct alignment and valve position.
Procedure for mounting the CMQ quarter-turn actuator, covering drive coupling and stop bolt settings.
Detailed steps for adjusting stop bolts for CMQ actuators, for seating and non-seating valve types.
Procedure for mounting CMR rotary actuators, focusing on drive coupling, alignment, and flange fixings.
Guidelines for electrical installation, including cable entries, terminal connections, and cover removal precautions.
Ensuring power isolation, voltage checks, circuit breaker inclusion, and overcurrent protection.
Introduction to the basic setup process, outlining key steps required after actuator mounting.
Instructions on setting the actuator to Local operation mode, essential for setting travel limits.
Procedure to adjust output torque or thrust settings to prevent valve jamming during setup.
Configuring how the actuator stops at end of travel: Position Limit or Force/Torque application.
Procedure to set the closed end of travel limit for the actuator using the manual jog function.
Procedure to set the open end of travel limit for the actuator using the manual jog function.
Setting the 4-20 mA signal calibration for the actuator's closed position and understanding error correction.
Step-by-step guide to calibrate the zero setpoint using an external 4-20 mA signal.
Step-by-step guide to calibrate the span setpoint using an external 4-20 mA signal.
Final steps for basic setup, including setting to Remote operation and refitting the top cover.
Configuring Reserve Power Pack actions on power loss, including position, timeout, speed, and control overrides.
ATEX and IECEx certifications for hazardous areas, including flamepath ratings and temperature limits.
Critical flamepath dimensions for ATEX and IECEx approved actuators.
Covers electrical hazards, ESD, enclosure materials, hand operation, local controls, and reserve power pack safety.
Steps for commissioning the actuator, including tools, valve position, and setup steps.
Detailed instructions for installing the actuator, including safety guidelines and handwheel operation.
Details on optional local controls, selector operation, and external LCD display.
Explanation of the Reserve Powerpack function for operation during power failure.
Procedure for mounting the CML linear actuator to the valve, emphasizing correct alignment and valve position.
Procedure for mounting the CMQ quarter-turn actuator, covering drive coupling and stop bolt settings.
Detailed steps for adjusting stop bolts for CMQ actuators, for seating and non-seating valve types.
Procedure for mounting CMR rotary actuators, focusing on drive coupling, alignment, and flange fixings.
Guidelines for electrical installation, including cable entries, terminal connections, and cover removal precautions.
Ensuring power isolation, voltage checks, circuit breaker inclusion, and overcurrent protection.
Introduction to the basic setup process, outlining key steps required after actuator mounting.
Instructions on setting the actuator to Local operation mode, essential for setting travel limits.
Procedure to adjust output torque or thrust settings to prevent valve jamming during setup.
Configuring how the actuator stops at end of travel: Position Limit or Force/Torque application.
Procedure to set the closed end of travel limit for the actuator using the manual jog function.
Procedure to set the open end of travel limit for the actuator using the manual jog function.
Setting the 4-20 mA signal calibration for the actuator's closed position and understanding error correction.
Step-by-step guide to calibrate the zero setpoint using an external 4-20 mA signal.
Step-by-step guide to calibrate the span setpoint using an external 4-20 mA signal.
Final steps for basic setup, including setting to Remote operation and refitting the top cover.
Configuring Reserve Power Pack actions on power loss, including position, timeout, speed, and control overrides.
| Brand | rotork |
|---|---|
| Model | CML-750 |
| Category | Controller |
| Language | English |