CODE SCREEN DISPLAY INDICATION OPERATOR SOLUTION
E046 Main Dump Open Circuit Open circuit on the Main Dump Output. Call installer or service technician.
E053 No Dump Supply
No supply (power or ground) on the selected dump
supply.
Check 5A dump fuse.
E054
Keyswitch Override –
High Side
Override Key has been turned to the override position -
key cannot be removed from the switch
Turn override key to position where key can
be removed.
E055
Keyswitch Override –
Low side
Override Key has been turned to the override position -
key cannot be removed from the switch
Turn override key to position where key can
be removed.
E064 Slew Disabled
Slew function disabled – No slewing allowed in the
selected program
Select correct program either manually or
for automatic make sure machine is setup
E065 P/Tdx Bottom Error
Bottom pressure transducer reading below 3.75mA –
5400 - 5410 counts.
Call installer or service technician.
E066 P/Tdx Top Error
Top pressure transducer reading below 3.75mA – 5400 -
5410 counts.
Call installer or service technician