EasyManua.ls Logo

Saimo 6101 - Page 61

Saimo 6101
101 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6101
6101
6101
6101 Belt
Belt
Belt
Belt Scale
Scale
Scale
Scale Integrator
Integrator
Integrator
Integrator Operating
Operating
Operating
Operating and
and
and
and Service
Service
Service
Service Manual
Manual
Manual
Manual
55
Pressing DONE CAL soft key enters the following screen: Pressing DONE CAL soft
key enters the following screen:
When material calibration is finished, input the standard weight value and press SURE
soft key to validate it and enter the following screen.
Pressing MATL FACR soft key enters the following screen:
Material factor is used to verify simulated contant of R-Cal, test weight Cal, and test chain
Cal. It takes material calibration data as standard to verify the difference between simulated
calibration and material calibration to make simulated Calibration much more closer to
material calibration.
2006-3-21 12:00:00 Scale#1
8 000000 t
Old Span [ 888 ]
New Span
Material calibration, please wait
Refer weight
BGIN RE- ENTR
CAL INPT
2006-3-21 12:00:00 Scale#1
8 000000 t
Old Span [ 888 ]
New Span [ 1000 ]
Material calibration complete
Span err [ -11.2% ]
BGIN EXIT MATL ADD ENTR
CAL CAL FACR REFR SPAN
2006-3-21 12:00:00 Scale#1
8 000000 t
Old factor [ 0% ]
New factor [1.0 ]
Sure new factor?
BGIN EXIT ENTR
CAL FACR FACR