Pressing “ DONE CAL ” soft key enters the following screen: Pressing “ DONE CAL ” soft
key enters the following screen:
When material calibration is finished, input the standard weight value and press “ SURE ”
soft key to validate it and enter the following screen.
Pressing “ MATL FACR ” soft key enters the following screen:
Material factor is used to verify simulated contant of R-Cal, test weight Cal, and test chain
Cal. It takes material calibration data as standard to verify the difference between simulated
calibration and material calibration to make simulated Calibration much more closer to
material calibration.
2006-3-21 12:00:00 Scale#1
8 000000 t
Old Span : [ 888 ]
New Span :
Material calibration, please wait !
Refer weight :
BGIN RE- ENTR
CAL INPT
2006-3-21 12:00:00 Scale#1
8 000000 t
Old Span : [ 888 ]
New Span : [ 1000 ]
Material calibration complete !
Span err : [ -11.2% ]
BGIN EXIT MATL ADD ENTR
CAL CAL FACR REFR SPAN
2006-3-21 12:00:00 Scale#1
8 000000 t
Old factor : [ 0% ]
New factor : [1.0 ]
Sure new factor?
BGIN EXIT ENTR
CAL FACR FACR