EasyManua.ls Logo

Saimo 6101 - Page 64

Saimo 6101
101 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6101
6101
6101
6101 Belt
Belt
Belt
Belt Scale
Scale
Scale
Scale Integrator
Integrator
Integrator
Integrator Operating
Operating
Operating
Operating and
and
and
and Service
Service
Service
Service Manual
Manual
Manual
Manual
58
reserve value
3.2.3
3.2.3
3.2.3
3.2.3 System
System
System
System data
data
data
data setup
setup
setup
setup
Pressing 3 from Main Menu enters the first page of the System Data Menu.
Display Data 1 :
Press the Up/Down scroll keys to scroll the cursor to the submenu desired, use numeric key
or Select input to input value.
Description Range
Zero dead 0% 100%
Supplementary S peed Load
Filter Constant 0 100
Language {} Chinese ENGLISH
[Zero Dead] During a run period, a total lower than the preset Zero Dead will not be added
into the master total.
2006-3-21 12:00:00 Scale#1
DISPLAY
DATA
1
Zero Dead
[ 0% ]
Supplementary [ SPEED ]
Filt Constant [ 10 ]
Language [ English ]
Press ↑↓ key, then press ENT!
MAIN PAGE
MENU DOWN
2006-3-21 12:00:00 Scale#1
1 INITIAL SETUP
2 CALIBRATION
3 SYSTEM
DATA
4 I/O DEFINITION
5 COMMUNICATION
Press a numeric key to select.
PREV PAGE
RUN DOWN