Pressing “ 3 ” from Main Menu enters the first page of the System Data Menu.
“ Display Data 1 ” :
Press the Up/Down scroll keys to scroll the cursor to the submenu desired, use numeric key
or “ Select input ” to input value.
Description Range
Zero dead 0% 100%
Supplementary S peed Load
Filter Constant 0 100
Language {} Chinese ENGLISH
[Zero Dead] : During a run period, a total lower than the preset Zero Dead will not be added
into the master total.
2006-3-21 12:00:00 Scale#1
DISPLAY
DATA
1
Zero Dead
:
[ 0% ]
Supplementary : [ SPEED ]
Filt Constant : [ 10 ]
Language : [ English ]
Press ↑↓ key, then press ENT!
MAIN PAGE
MENU DOWN
2006-3-21 12:00:00 Scale#1
1 . INITIAL SETUP
2 . CALIBRATION
3 . SYSTEM
DATA
4 . I/O DEFINITION
5 . COMMUNICATION
Press a numeric key to select.