6101
6101
6101
6101 Belt
Belt
Belt
Belt Scale
Scale
Scale
Scale Integrator
Integrator
Integrator
Integrator Operating
Operating
Operating
Operating and
and
and
and Service
Service
Service
Service Manual
Manual
Manual
Manual
92
4.3.4
4.3.4
4.3.4
4.3.4 Current
Current
Current
Current Output
Output
Output
Output (Optional)
(Optional)
(Optional)
(Optional)
Refer to Figure 4 -4 Current Output Diagnostics Flow Chart, check the flowrate at different
current output ranging from 4mA to 20mA (full range) at a certain interval. In order to check
the flowrate at 4mA current output, power up the 6101 and run the belt empty. If the flowrate
indication is not zero, reset it by performing zero calibration. Remove the connections from
the current output terminals which are then connected to the DC milli-amperometer correctly
(Note that the range of milli-amperometer should exceed 20mA). At this time the current
output on the milli- amperometer should be 4mA. If a minor deviation is found, the reading
can be corrected by adjusting the potentiometer. However, in case that a remarkable
deviation exists, the current output board is bad and needs to be changed.
When the 6101 gives correct current output at zero flowrate, the current output at various
known flowrates should be checked. Apply reference weights on the scale and press RUN
key on the 6101 integrator to determine the flowrate at a percentage of the full load. For
example, a belt scale with scale capacity of 100t/h displays 10 , then the reference weight
is 10% of the scale capacity. In this case the milli-amperometer shall give a reading with the
same percentage of the full scale. For this example, the reading of the milli-amperometer
shall be 16 (20-4)X10%+4mA = 5.6mA. If incorrect reading occurs, the current output board
should be repaired or changed.