Because the belt scale is a dynamic measuring equipment. The weighing accuracy has a close relation
with the conveyor. Select a certain period of running time to measure the tare and calculate the average
value.
The test duration should be set to a value equivalent to over one belt revolution or greater than 6min.
Pressing MANL DURA soft key enters the following screen:
Input the settings for Belt Length, Revolution and Running time on this menu.
Pressing BGIN DURA soft key enters the following screen:
2006-3-21 12:00:00 Scale #1
8 000000 t
888 t/h
1m/s
Establishing test duration, Please wait!
[ 10 ]
BGIN PAGE
DURA UP
2006-3-21 12:00:00 Scale#1
MANUAL TEST DURATION
DATA
Belt Length: [ 10 m ]
Revolutions: [ 1 ]
Running Time: [ 10 s ]
Press
or
key, then press ENT!
BGIN PAGE
DURA UP