EasyManua.ls Logo

Salda SMARTY XP - Technical Data

Salda SMARTY XP
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10 | EN SMARTY v2023.1
4.3. TECHNICAL DATA
SMARTY 2X P 1.1 2X P 1.2
2X P
S300 3X P 1.1 3X P 1.2
3X P
S300
4X P F2
1.1
4X P F2
1.2
4X P
S300
Exhaust air fan
phase/voltage [50 Hz/VAC] 1/230 1/230 1/230
SRZHUFXUUHQW [kW/A] 0,05/0,4 0,09/0,75 0,17/1,35
speed [min
-1
] 4525 3200 4120
control input [VDC] 0-10 0-10 0-10
protection class IP44 IP54 IP54
Supply air fan
phase/voltage [50 Hz/VAC] 1/230 1/230 1/230
SRZHUFXUUHQW [kW/A] 0,05/0,4 0,09/0,75 0,17/1,35
speed [min
-1
] 4525 3200 4120
control input [VDC] 0-10 0-10 0-10
protection class IP44 IP54 IP54
7RWDOSRZHUFXUUHQW
consumption
[kW/A] 0,16/1,05 0,16/1,05 0,15/1,02 0,23/1,75 0,23/1,75 0,23/1,7 0,4/2,95 0,4/2,95 0,39/2,92
Automatic control integrated miniMCB
miniMCB
basic
S300 miniMCB
miniMCB
basic
S300 miniMCB
miniMCB
basic
S300
,QVXODWLRQRIZDOOV [mm] 20 30 30
([KDXVWDLU¿OWHUFODVV
dimensions LxWxH)
[mm] 03/[[&RDUVH 03/[[&RDUVH 03/[[&RDUVH
6XSSO\DLU¿OWHUFODVV
dimensions LxWxH)
[mm] 03/[[&RDUVH 03/[[&RDUVH 03/[[&RDUVH
Device protection class IP-34 IP-34 IP-34
SMARTY 2X V 1.1 2X V 1.2
2X V
S300 3X V 1.1 3X V 1.2
3X V
S300
4X V F2
1.1
4X V F2
1.2
4X V
S300
Exhaust air fan
phase/voltage [50 Hz/VAC] 1/230 1/230 1/230
SRZHUFXUUHQW [kW/A] 0,04/0,35 0,08/0,75 0,17/1,35
speed [min
-1
] 4060 3200 4120 4600
control input [VDC] 0-10 0-10 0-10
protection class IP54 IP54 IP54
Supply air fan
phase/voltage [50 Hz/VAC] 1/230 1/230 1/230
SRZHUFXUUHQW [kW/A] 0,04/0,35 0,08/0,75 0,17/1,35
speed [min
-1
] 4060 3200 4120 4600
control input [VDC] 0-10 0-10 0-10
protection class IP54 IP54 IP54
Integrated electrical
preheater
[kW] 0,6
- -1,2-
-
1,2 - -
7RWDOSRZHUFXUUHQW
consumption
[kW/A] 0,74/3,62 0,14/0,95 0,13/0,92 1,43/7 0,23/1,75 0,23/1,7 1,6/8,15 0,4/2,95 0,39/2,92
Automatic control integrated miniMCB
miniMCB
basic
S300 miniMCB
miniMCB
basic
S300 miniMCB
miniMCB
basic
S300
,QVXODWLRQRIZDOOV [mm] 30 30 30
([KDXVWDLU¿OWHU
(class, dimensions
LxWxH)
[mm] 03/[[&RDUVH 03/[[&RDUVH 03/[[&RDUVH
6XSSO\DLU¿OWHU
(class, dimensions
LxWxH)
[mm] 03/[[&RDUVH 03/[[&RDUVH 03/[[&RDUVH
Device protection class IP-34 IP-34 IP 34
According to EN 13141-7.
$FRXVWLFGDWDFKHFNWKHSURGXFWSDJHRQZZZVDOGDOW
Not suitable for installation in living rooms: additional noise insulation required.

Table of Contents

Related product manuals