EB 3136 EN 15
Measures for preparation
Special storage instructions for elastomers
Elastomer, e.g. actuator diaphragm
To keep elastomers in shape and to pre-
vent cracking, do not bend them or hang
them up.
We recommend a storage temperature of
15°C for elastomers.
Store elastomers away from lubricants,
chemicals, solutions and fuels.
SAMSON's After-sales Service department
can provide more detailed storage instruc-
tions on request.
Tip
4.4 Preparation for installation
Proceed as follows:
Î Flush the pipelines.
The plant operator is responsible for clean-
ing the pipelines in the plant.
Î Check the valve to make sure it is clean.
Î Check the valve and actuator to make
sure they are not damaged.
Î Check to make sure that the type desig-
nation, valve size, material, pressure rat-
ing and temperature range of the valve
and actuator match the plant conditions
(size and pressure rating of the pipeline,
medium temperature, etc.).
Î Check any mounted pressure gauges to
make sure they function.
Note