EasyManua.ls Logo

Samson 3510 - 1.1 Notes on Severe Personal Injury

Samson 3510
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EB 8091-1 EN 7
Safety instructions and measures
Referenced standards and regulations
The control valves comply with the requirements of the European Pressure Equipment Direc-
tive 2014/68/EU.
According to the ignition risk assessment performed in accordance with EN13463-1:2009,
section 5.2, the non-electrical control valves do not have their own potential ignition source
even in the rare incident of an operating fault. As a result, they do not fall within the scope of
Directive 2014/34/EU.
Î For connection to the equipotential bonding system, observe the requirements specied in
section 6.4 of EN60079-14 (VDE0165 Part 1).
Referenced documentation
The following documents apply in addition to these mounting and operating instructions:
Mounting and operating instructions for mounted actuator, e.g. uEB8310-1 for
Type3271 and Type3277 Pneumatic Actuator with 120cm² actuator area
Mounting and operating instructions for mounted valve accessories (positioner, solenoid
valve etc.)
uAB0100 for tools, tightening torques, and lubricant
For oxygen service: Manual uH01
1.1 Notes on possible severe personal injury
DANGER
!
Risk of bursting in pressure equipment.
Control valves and pipelines are pressure equipment. Improper opening can lead to
valve components bursting.
Î Before starting any work on the control valve, depressurize all plant sections
concerned as well as the valve.
Î Drain the process medium from all the plant sections concerned as well as the
valve.
Î Wear personal protective equipment.