. ADJUSTMENT
2. Calibration
For a stable light source, wait for 30 mins after turning on the power of the light source prior to
calibration.
Adjust the brightness and the color temperature using the color thermometer for photography and the
LV checker as below.
Calibration is performed in the following sequence with a K10D master body.
3. Master body and photometric standard lens set-up
Set the mode dial to
M
.
Set the focus mode lever to
MF
.
Set the SR lever to
OFF
.
Install the photometric standard lens for adjustments and the F8 set ring on the body.
Set the aperture stop of the photometric standard lens to
F8
.
4. Calibration procedure
Connect the AC adaptor to the camera (master body).
Access to the PC using the USB cable.
Turn on the camera and check that the camera is recognized by the PC.
Set the light box to
LV12
.
Position the lens on the top center of the light box.
Light Brightness Color temperature
LV12
LV12.00Ev ±0.50 2,856K ±30
LV11
LV11.00Ev ±0.01
-