. ADJUSTMENT
✁
Cover the whole camera and the rest of the top section.
✂
Double click on the “77010_M-Test_CS_Ver_.exe” file in the
✄
77010-M-Test CS
☎
folder.
✆
Enter the lens ID no. and click on “OK” on the lens input screen. (e.g.:123)
✝
Click on “Yes (Y)” if the lens no. is entered correctly.
✞
The digital adjustment screen appears. Click on the icon for calibration at the top left of the screen.
✟
The calibration screen appears. Click on the “Enter” key (or “START” button).
(Release 15 times about for 35 secs.)