5-1-7. Option TABLE
To do list
7) Temperature changing table of ice room
Set item Ice Room Temp Shift
Reference Fridge Room 7-SEG
Value 34
ex) If you want to change the ice room standard temperature to
+5℉(+2.5℃)
5. Check the installation status
5-1. Function for failure diagnosis
Setting value
FZ
Compartment
code
Temp.
compensation
0 0℉(0.0℃)
1 -1℉(-0.5℃)
2 -2℉(-1.0℃)
3 -3℉(-1.5℃)
4 -4℉(-2.0℃)
5 -5℉(-2.5℃)
6 -6℉(-3.0℃)
7 -7℉(-3.5℃)
8 +1℉(+0.5℃)
9 +2℉(+1.0℃)
10 +3℉(+1.5℃)
11 +4℉(+2.0℃)
12 +5℉(+2.5℃)
13 +6℉(+3.0℃)
14 +7℉(+3.5℃)
15 +8℉(+4.0℃)
8) Temperature changing table of Ice Maker
Dropping Temperature
Set item
Ice Maker Dropping
Temperature
Reference Fridge Room 7-SEG
Value 35
ex) If you want to change the mid drawer room temperature to
-2
℉(-1.0℃)
Setting value
FZ
Compartment
code
Temp.
compensation
0 -13℃
1 -12℃
2 -11℃
3 -10℃
4 -14℃
5 -15℃
6 -16℃
7 -17℃
151