LG_MULTI_F_3828A20097W_1[1]
4-1-1-2-2. Forced Defrost Function
2-1) When it is on the Forced Operation during the Test Mode, press any button once.
Then, the Forced Operation will stop
immediately and it will go into the
When it starts the Forced F-Defrost, the temperature LED Lamps indicating 3℃, 5℃ and 7℃ will be on
showing that it is on the Forced F-Defrost.
2-2) At this time, it sends out "Beeping" sound for 3 seconds. This alarm sound repeats 0.75 sec On and 0.25
sec Off which keeps on until the Forced F-Defrost finishes.
3) Test Cancellation Mode
3-1) When turning the display panel into the Test mode and pressing the any button once more during the
Forced F-Defrost, the Forced F-Defrost will be
cancelled and it will go back to
Also, when the unit is plugged out and in again, the Test mode is to be deactivated.
[Note] Models with the Rotary Switch operate the
same as the above with th
e Forced Defrost Mode on.