Network disconnection
You can receive and save events of a physically disconnected network.
1. From the Setup menu, select the
<Event (
)> tab.
2. Click <Event setup>.
3.
Select
<Network disconnection>
from
<Event action setup>
.
4.
Set whether or not to
<
Enable
>
.
5. Specify the activation time and
activation condition.
`
For more information about <Activation
time> and <Action>, refer to “Alarm input”.
(page 95)
6. When done, click [Apply (
)].
Alarm output setup
1. From the Setup menu, select the
<Event ( )> tab.
2. Click <Alarm output setup>.
3. Set the camera’s type of alarm output.
`
If you change the alarm output type, the alarm
out button on the monitoring page and alarm
output type displayed on Event Setup page will
be changed accordingly.
• Type
- Normal open : Considers “Open circuit” status of the sensor or alarm input device
as normal, and triggers alarm event if becomes “Closed circuit” status.
- Normal close : Considers “Closed circuit” status of the sensor or alarm input device
as normal, and triggers alarm event if becomes “Open circuit” status.
English _105
● SETUP SCREEN