69
Primary Source
Specify Primary Source for the automatic input source.
Secondary Source
Specify Secondary Source for the automatic input source.
The Secondary Source function is disabled if Primary Source is set to All.
Power Control
MENU mSystem Power ControlENTER E
Auto Power On
This feature automatically turns on the product as soon as it is plugged in. Pressing the power
button is not needed.
Off / On
PC Module Power
The PC module can be turned on/off separately from the LFD.
Synced Power-On
To turn off the LFD without turning off the PC module, select Off.
Off / On
Synced Power-Off
To turn on the PC module without turning on the LFD, select Off.
Off / On
Standby Control
You can set the screen standby mode to be applied when an input signal is received.
Auto
Power-saving mode will activate if no input signals are detected even though a source
device is connected to the display.
The message No Signal will appear if no source device is connected.
Off
The message No Signal will appear if no input signals are detected.
If No Signal is displayed although a source device is connected, check the cable
connection.
If No Signal Message is set to Off, the No Signal message does not appear.
If this is the case, set No Signal Message to On.
On
Power-saving mode will activate if no input signals are detected.
Network Standby
This feature keeps the network power on when the product turns off.
Off / On
Power Button
The power button can be set to either turn on the power or turn on/off the power.
Power On Only: Set the power button to turn on the power.
Power On/Off: Set the power button to turn on/off the power.