TPMS1209C01 User Manual
Page 13 of 23
Warning of Low Battery Power
Function: The system will issue a warning alarm when the battery power is
too low to afford the monitor to work.
Alarm mode: The beep buzzes twice shortly and stops, the battery icon
flashes continually.
Treatment: Replace the batteries or connect the monitor to the lighter plug immediately.
Alarm Record Inquiry
The monitor will issue an alarm when the tire is under the improper status. And the monitor will record the
alarm. User can inquire alarm record in this interface. The system can record the latest 10 alarms. When
there are 10 alarm records saved in monitor, the new alarm will be saved and the earliest alarm will be
deleted automatically.
Under the normal mode, press E key for 3 seconds to enter the monitor
programming interface, the screen display the index interface 1.
Press S key to switch to index interface 5, then press E key to enter the alarm
record inquiry interface.
Alarm Record Number
If there is no alarm record, the screen will display “- - -”
If there is alarm record, the latest one alarm will be displayed
.
Press S key to switch between alarm records. The system can record the
latest 10 alarms. Press S key to switch the alarm record number from 1 to
10.