EasyManua.ls Logo

Sanwa CD731 - Maximum Overload Protection Input

Sanwa CD731
57 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
−30−
Maximum overload
protection input
Maximum rating
input value
Function Input
5. Never use meter if the meter or test leads are damaged or
broken.
6. Never use uncased meter.
7. Be sure to use a fuse of the spesified rating or type. Never
use a substitute of the fuse or never make a short circuit of
the fuse.
8. Always keep your fingers behind the finger guards on the
probe when making measurements.
9. Be sure to disconnect the test pins from the circuit when
changing the function or range.
10. Be sure to disconnect the test pins from the circuit when
changing the function or range.
11. Never use meter with wet hands or in a damp environment.
12. Never open tester case except when replacing batteries or
fuse. Do not attempt any alteration of original specifications.
13. Do not use the device near an item of strong electromagnetic
generation or a charged item.
14. To ensure safety and maintain accuracy, calibrate and check
the tester at least once a year.
15. Indoor use
1-3 Maximum Overload Protection Input
DCV
ACV
V
COM
DC1000V
AC750V
DC1000V,AC750V
or PEAK MAX 1000V
DCAC500V
or PEAK MAX 700V
0.5A/250V
Fuse protected
0.5A/250V
Fuse protected
0.5A/250V
Fuse protected
20A/250V
Fuse protected
Voltage and current
input prohibited
DC/AC 32μA
DC/AC 3200μA
DC/AC 320mA
DC/AC 20A
10sec.
Ω・
COM
μAmA
COM
μAmA
COM
μAmA
COM
20A
COM
Ω・ ・
DC/AC
32μA
DC/AC
320μA3200μA
DC/AC
32mA320mA
DC/AC
20A

Related product manuals