EasyManua.ls Logo

Sanyo Big PACi 18 Series - Page 80

Sanyo Big PACi 18 Series
275 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-75
1
1-3. Other Component Specifi cations
Outdoor Units SPW-C706VH8
MODEL No.
Outdoor Unit SPW-C706VH8
Power Transformer
Rated
Source VAC, Hz
Secondary
Coil resistance
Thermal cut off temperature °C
Thermistor (Coil / Air sensor): TH1, TH2, TH3, TH4
KTM-35D-S1, DTN-C532G3H
Resistance
k
–10°C: 23.7±5% 20°C: 6.5±5%
–5°C: 18.8±5% 30°C: 4.4±5%
0°C: 15.0±5% 40°C: 3.1±5%
5°C: 12.1±5% 45°C: 2.6±5%
10°C: 9.7±5% 50°C: 2.1±5%
Thermistor (Discharge gas sensor): TH5
CM-12
Resistance
k
60°C: 12.4±5% 90°C: 4.6±5%
70°C: 8.7±5% 100°C: 3.4±7%
75°C: 7.4±5% 110°C: 2.5±7%
80°C: 6.3±5% 120°C: 1.9±7%
85°C: 5.3±5% 130°C: 1.5±7%
Relay (Comp. Magnetic Contactor)
Coil rated VAC
Contact rating VAC, A
Coil resistance (at 20°C)
Sol-Control-Valve
Sol-control-valve UKV-25D18
Magnetic coil UKV-A053 (062), DC 12 V
4 way valve
4 way valve STF-0401G
Electro magnetic coil STF-01AI518A1, AC 220-240 V, 50Hz / 60Hz
SM830161Book.indb75SM830161Book.indb75 2008/05/1920:33:192008/05/1920:33:19